2. Measuring DC voltage, current and power
The examples in this chapter are bundled with TinyCAD. Choose Open Example → SPICE tutorial, select the named example, then choose Open Drawing. No download is needed.
Open divider. Keep the nominal 5 V source and two 1 kΩ resistors. The aim is to distinguish node voltage, voltage across a device, current through it and power absorbed by it.
Voltage measurements
out means the voltage of OUT relative to node 0. The voltage across R1 is
VIN − VOUT, which is also 2.5 V here. This equality is accidental: after changing
R2 to 2 kΩ, R1 has 1.667 V while R2 has 3.333 V.
Use Simulation → SPICE → Insert Probe for a node voltage. A differential probe measures its positive terminal minus its negative terminal. Connect its positive tip to IN and negative tip to OUT to measure R1. Reversing the tips reverses the result. A differential probe is especially useful when neither terminal is grounded, such as a coupling capacitor or a bridge output.
Current measurements
Use a series-current probe by breaking a wire and inserting the probe in the
path. It is modelled as a zero-volt source: current flows through it with no
ideal voltage drop. Connecting it across the supply instead would short the
supply. Positive probe current follows the probe’s positive-to-negative terminal
order. Source branch currents, such as v1#branch, are also available directly.
For this divider, current flows from V1 through R1 and R2 towards ground. Both resistor currents are 2.5 mA; V1’s branch current is −2.5 mA because it supplies that current from its positive terminal.
Power and an energy-balance check
Use the passive sign convention: P = V × I, with current entering the terminal
at which voltage is defined positive. Positive power is absorbed; negative power
is delivered.
| Device | Calculation | Nominal result |
|---|---|---|
| R1 | (2.5 V)² / 1 kΩ |
+6.25 mW |
| R2 | (2.5 V)² / 1 kΩ |
+6.25 mW |
| V1 | 5 V × (−2.5 mA) |
−12.5 mW |
| Sum | Supply plus loads | 0 W |
This balance is a useful debugging tool. A factor of 1000 often indicates a prefix mistake. An incorrect sign often indicates reversed probe orientation. An unexplained extra load may reveal an unintended junction or a meter connection.
TinyCAD’s Measurements controls can select component voltage, current and power where the model supports them. A missing supported current vector is reported as unavailable; it must not be interpreted as zero consumption.
Sweep the supply
Open dc-sweep. The saved DC sweep uses V1, starting at 0 V, stopping at 10 V and incrementing by 0.5 V. Run and plot OUT.

The horizontal axis is the swept source value, not time. Expected values are 0 V, 2.5 V and 5 V at supply values of 0 V, 5 V and 10 V. The slope is 0.5 V/V. This test is useful for checking bias networks and sensor interfaces before adding time-dependent stimuli.
Investigate loading
Add another 1 kΩ resistor from OUT to ground. R2 and the new load are in parallel,
so their equivalent resistance is 500 Ω. The expected output is now
5 × 500 / (1000 + 500) = 1.667 V. A voltage divider is not an ideal voltage
source: its output changes when it supplies current.
For a measurement checklist, record the node names, reference direction, units, source settings and analysis. That information makes a result reproducible and allows another reader to distinguish a circuit change from a plotting change.
Download the lesson circuits
The same examples are already available in Open Example. For an independent copy, download a .dzn drawing and use File → Open in TinyCAD. The .cir companion is SPICE text for inspection or a compatible external simulator, not a TinyCAD drawing. XSPICE circuits require Desktop for fresh runs.
| Example | Drawing | Netlist |
|---|---|---|
| divider | TinyCAD drawing | SPICE text |