4. Transient analysis: charging a capacitor
The examples in this chapter are bundled with TinyCAD. Choose Open Example → SPICE tutorial, select the named example, then choose Open Drawing. No download is needed.
Open rc-step. A source steps from 0 to 1 V through 1 kΩ into a 1 µF capacitor. The saved transient lasts 5 ms with a maximum step of 5 µs. Plot IN and OUT together.
Video: rc charging and time constant
Refining the maximum timestep and measuring OUT at 1 ms and the RC time constant.
Circuit and reference results


Why the output curves rather than jumps
Capacitor current is i = C × dv/dt. Immediately after the input changes, the
capacitor is still near 0 V, so almost the full input appears across R1. The
initial current is approximately 1 V / 1 kΩ = 1 mA. As the capacitor charges,
the resistor voltage and current decrease. The output approaches 1 V rather
than reaching it instantaneously.
The time constant is τ = R × C = 1 ms. For an ideal step and an initially
uncharged capacitor, VOUT(t) = 1 − exp(−t/τ) volts.
| Time after the step | Expected OUT |
|---|---|
| 1 ms = 1τ | 0.632 V |
| 2 ms = 2τ | 0.865 V |
| 3 ms = 3τ | 0.950 V |
| 5 ms = 5τ | 0.993 V |
The supplied source rises over 1 µs, so expect a small difference from the
instantaneous-step equation. Use the chart cursor or a Value measurement
at 1 ms. A Time constant measurement with initial 0 V and final 1 V should
give about 1 ms. A Rise time measurement uses the 10–90% interval: its
expected value is ln(9) × τ ≈ 2.197 ms, not 1 ms.
Duration and maximum step answer different questions
Duration determines how long the experiment runs. Maximum step limits the solver’s spacing between time points. The solver may take smaller steps near edges or nonlinear events. The number of samples therefore need not equal duration divided by maximum step.
With too short a duration, settling is invisible. With too coarse a timestep, edges and peaks can be poorly measured even if the plot looks plausible. Reduce the maximum step from 5 µs to 2.5 µs and compare the 1 ms reading; a stable result should change very little. This is a convergence check on the measurement, not merely a check that the solver reports success.
Initial conditions and energy
Normally SPICE solves a DC operating point before starting the transient.
Checking initial conditions requests the alternative initial-condition
startup path (uic). Use it deliberately, with appropriate capacitor/inductor
initial conditions; it is not a universal cure for convergence problems.
This example does not need it because the input’s initial value is zero.
At 1 V the capacitor stores E = ½CV² = 0.5 µJ. During charging, R1 dissipates
energy and the source supplies both the stored and dissipated energy. Instantaneous
power and accumulated energy are different measurements: integrate power over
the chosen interval to obtain joules.
Try 2.2 kΩ, predict a 2.2 ms time constant, and extend duration to 11 ms. Then restore R1 and halve C1: the time constant should halve. These changes illustrate how to design an experiment that distinguishes a component’s effect from a plotting artefact.
Download the lesson circuits
The same examples are already available in Open Example. For an independent copy, download a .dzn drawing and use File → Open in TinyCAD. The .cir companion is SPICE text for inspection or a compatible external simulator, not a TinyCAD drawing. XSPICE circuits require Desktop for fresh runs.
| Example | Drawing | Netlist |
|---|---|---|
| rc-step | TinyCAD drawing | SPICE text |